Firmware & Releases
ASC release notes v. 1.2.3
These release notes cover ASC 1.2.2 and 1.2.3. Supported servers are unchanged: Aylook 8.1, 9.0, 9.1 and 9.2 or newer. Aylook 9.2.4 ships with ASC 1.2.3.
User management (Setup > Users)
- On Aylook 9.2, a new user is created with a password typed by the administrator and confirmed. The password is checked against the server's password policy before it is sent: at least 11 characters, three kinds of character, no spaces, no more than three identical characters in a row, and it must not contain the user name.
- «Account enabled» and «Valid until» can be set when a user is created. A new user is enabled and valid until 2099-12-31 by default. Both are shown as columns in the users table.
- Deleting a user works again: before, the server refused the request.
- Passwords typed in the user settings are no longer written to the client log.
- The empty "User profiles" and "User access control" tabs have been removed.
Arm/disarm
- The arm/disarm controls are shown only when the Aylook has the Arm/disarm licence module active: the Armed/Disarmed button in the main toolbar, the armed mode selector in Advanced Sensors, and the lock icon on cameras in the resources list.
Performance and stability
- Each open ASC window (main and detached) uses about 140 MB less memory.
- When ASC runs as the network monitor of an Aylook, it no longer uses about two processor cores and over 1 GB of memory, and it no longer restarts every few minutes. The problem had been present since ASC 1.0.43.
- After a crash of the display, ASC now recovers by itself instead of closing.